Check md-raid

Overview

Reports the health of the Linux software RAID arrays (md) on this host: how many member devices each array is running on, which of them the kernel has thrown out, what it says about each of the remaining ones, whether a resync, recovery or reshape is under way or frozen, and how many inconsistent sectors the last consistency check found. Every array the kernel knows is reported, so an array nobody remembers is on the list as well. Alerts when an array has lost the redundancy it was built for, when the kernel declares it failed, when a parity array has lost the write journal it needs in order to accept writes at all, when the kernel says a member wants replacing or has seen a write error, and when a consistency check found differences between the members of a parity array. With --spares it also alerts when an array holds fewer spare devices than it is supposed to. Supports extended reporting via --lengthy.

What the kernel reports:

An array is in exactly one of these states, and the check takes the word from the kernel rather than deriving one of its own:

State Meaning
active The array is running. It may still be missing members, which is what the device counters below say.
active (read-only) Someone put the array into read-only mode with mdadm --readonly. Not a fault.
active (auto-read-only) The array was assembled and has not been written to yet, so the kernel is holding back the resync it would otherwise start. The first write switches it to active. Not a fault.
inactive The array was assembled but never started, because not enough of its members turned up.
broken The array has lost so many members that it can no longer serve its data.

Below that, a redundant array reports how many members it wants and how many are in sync, as 3/4 [_UUU]: three of four slots are filled, and the first one is not.

Important Notes:

  • RAID 0 and linear arrays report almost nothing, and that is not a gap in the check. They have no redundancy, so the kernel gives them no device counters, no degraded attribute and no consistency check. A member that fails while it is still plugged in is invisible: the array keeps reporting active and the I/O errors go to whoever was reading. Only a member that is really gone from the system flips the array to broken, and even that happens on the first I/O that touches it, not at the moment the disk disappears. Measured on kernel 7.1 by removing the member's PCI device: the array stayed active with every member still in_sync until something wrote to it. Where the data on a RAID 0 matters, the disks below it need disk-smart as well.
  • A consistency check is not run by itself. The mismatch_cnt this check reports is whatever the last check or repair run left behind, and it stays at that value until the next one runs. Both the Red Hat and the Debian family ship a timer or cron job for it (mdcheck_start.timer / mdcheck_continue.timer, or /etc/cron.d/mdadm); on a host where none of them is enabled, the number reported here is meaningless because nothing ever produced it.
  • A mismatch on a mirror is not the same finding as a mismatch on a parity array. md(4) is explicit about it: on RAID 5 and RAID 6 "any mismatches should indicate a hardware problem at some level - software issues should never cause such a mismatch", while on RAID 1 and RAID 10 a page written while the check reads it, and above all a swap area, leave the copies different in a place nothing ever reads back, so "the mismatch_cnt value can not be interpreted very reliably". That is why --mismatch-severity defaults to warn and --mirror-mismatch-severity to ok. Both numbers are always reported and always in the performance data, so a mirror whose count keeps growing from check to check is still visible on the graph.
  • The commands in the output name this host's array and this host's member. Where the check reports a problem, the mdadm lines it suggests carry the real names it just read, so they can be copied without being checked against the machine first. The one thing it cannot know is the device of the replacement disk, and the text asks for it in words rather than inventing a path.
  • Neither the kernel device nor the array name is a stable identifier, so both are reported. The kernel hands out md127 from a pool when the array is assembled, which can differ between boots on a host with several arrays, and the name an array was created under gains a <homehost>: prefix as soon as mdadm stops treating the array as local. Measured on a host still called localhost.localdomain, where the same array was /dev/md/raid5 after creation and /dev/md/localhost.localdomain:raid5 after the next boot. The kernel device is what every mdadm command and every path below /sys takes, so it is the identifier the check reports and labels its performance data with; --lengthy shows the name beside it, and --match and --ignore accept either.
  • A parity array that lost its write journal reports every member in sync and cannot be written to. A RAID 4, 5 or 6 array can keep a write journal on a device of its own to close the write hole. Where that device dies, /proc/mdstat keeps printing [3/3] [UUU], degraded stays at 0 and array_state stays clean, while reads run at full speed and writes do not: a direct write answers Input/output error, and a buffered write is reported to the application as having succeeded and then thrown away, with only lost async page write in the kernel log. Taking the dead journal out does not help and makes it worse, because then nothing is flagged anywhere and the array is indistinguishable from a healthy one. Measured on kernel 6.12 with mdadm 4.4. This check reads it either way and reports CRITICAL, from the journal member's own flag or, once that is gone, from consistency_policy still reading journal while no member carries the journal. --journal-severity changes it.
  • A member on its way out is invisible in /proc/mdstat. The kernel keeps three more words about each member next to the array, in /sys/block/*/md/dev-*/state, and prints none of them into /proc/mdstat: want_replacement means it wants this member replaced and will pull a spare in for it, write_error means a write to it failed and the bad block list absorbed it, and blocked means it has bad blocks nobody has acknowledged yet, so writes to it are waiting. An array carrying all three still reports [3/3] [UUU], which is what a check reading /proc/mdstat alone reports as healthy. Measured on kernel 7.1. --member-severity changes what these are worth.
  • A frozen sync stops an array from ever repairing itself. Writing frozen to sync_action forbids resync, recovery and reshape, and nothing clears it by itself. A degraded array in that state does not rebuild however many spares sit in it, and /proc/mdstat prints no line that would say why: it looks merely idle. Where the check finds one, it says so and gives the command that lets the sync run again.
  • A spare is only checked against a number somebody gave. The kernel does not know how many spares an array is supposed to hold, so nothing says a spare that quietly disappeared is missing. --spares pins the number, either once for every array or per array with --spares=md0=1, and the check alerts when an array holds fewer. This is what mdadm --monitor calls SparesMissing and takes from the spares= of its own configuration file, which this check does not read. RAID 0 and linear arrays are never graded against it, because they have nothing to rebuild onto.
  • A spare that stepped in does not close the case. Once the rebuild is done the array reports its full width again and the kernel's degraded counter is back to zero, while the member it threw out is still attached and still flagged. Nothing is degraded and a disk has died all the same, which is why the check keeps reporting such an array until the failed device is removed. The array also has no spare left, so the next failure has nothing to fall back on.
  • A rebuild does not raise the state by itself. An array that is recovering onto a spare is degraded, and the degradation is what alerts; the progress is reported next to it. An array that is merely resyncing after an unclean shutdown, being checked, or being reshaped, is not a problem and stays OK.
  • The count of inconsistent sectors is not the count of bad sectors. md works in units much larger than a sector, so a single error inside a 64 KiB unit adds 128 to the counter.
  • A host with no array at all reports WARN. An array is assembled from the superblocks on its members at every boot, so an array that used to be here and is gone is worth a look. Lower it with --no-arrays-severity=ok on a host that is meant to run the check without having an array.
  • Related checks: disk-smart reports the health of the disks the arrays are built on, disk-io their load, and fs-mounts whether what is on top of an array is actually mounted.

Data Collection:

  • Reads /proc/mdstat for the list of arrays, their members and the progress of a running resync, recovery, reshape or check
  • Reads array_state, consistency_policy, degraded, level, mismatch_cnt, raid_disks and sync_action below /sys/block/md*/md
  • Reads state below /sys/block/md*/md/dev-* for what the kernel says about each member device
  • Needs no root and no sudo, and calls no external command

Fact Sheet

Fact Value
Check Plugin Download https://github.com/Linuxfabrik/monitoring-plugins/tree/main/check-plugins/md-raid
Nagios/Icinga Check Name check_md_raid
Check Interval Recommendation Every minute
Can be called without parameters Yes
Runs on Linux
Compiled for Windows No

Help

usage: md-raid [-h] [-V] [--always-ok] [--ignore IGNORE]
               [--journal-severity {ok,warn,crit,unknown}] [--lengthy]
               [--match MATCH] [--member-severity {ok,warn,crit,unknown}]
               [--mirror-mismatch-severity {ok,warn,crit,unknown}]
               [--mismatch-severity {ok,warn,crit,unknown}]
               [--no-arrays-severity {ok,warn,crit,unknown}]
               [--no-match-severity {ok,warn,crit,unknown}] [--no-perfdata]
               [--severity {ok,warn,crit,unknown}] [--spares SPARES]
               [--spares-severity {ok,warn,crit,unknown}]

Reports the health of the Linux software RAID arrays (md) on this host: how
many member devices each array is running on, which of them the kernel has
thrown out, what it says about each of the remaining ones, whether a resync,
recovery or reshape is under way or frozen, and how many inconsistent sectors
the last consistency check found. Every array the kernel knows is reported, so
an array nobody remembers is on the list as well. Alerts when an array has
lost the redundancy it was built for, when the kernel declares it failed, when
a parity array has lost the write journal it needs in order to accept writes
at all, when the kernel says a member wants replacing or has seen a write
error, and when a consistency check found differences between the members of a
parity array. With --spares it also alerts when an array holds fewer spare
devices than it is supposed to. Supports extended reporting via --lengthy.

options:
  -h, --help            show this help message and exit
  -V, --version         show program's version number and exit
  --always-ok           Always returns OK.
  --ignore IGNORE       Any item matching this Python regex will be ignored.
                        Can be specified multiple times. Example:
                        `(?i)linuxfabrik` for a case-insensitive match.
  --journal-severity {ok,warn,crit,unknown}
                        State to report when a parity array (RAID 4, RAID 5,
                        RAID 6) that keeps a write journal has lost it. Such
                        an array reports every member in sync and cannot be
                        written to, and a buffered write to it is reported as
                        having succeeded and then thrown away. Default: crit
  --lengthy             Extended reporting.
  --match MATCH         Filter by this Python regular expression. Case-
                        sensitive by default; use `(?i)` for case-insensitive
                        matching. Can be specified multiple times. If both
                        `--match` and `--ignore` are given, an item must match
                        `--match` AND not match `--ignore` to be reported
                        (include first, exclude second). Examples:
                        `(?i)example` to match "example" regardless of case.
                        `^(?!.*example).*$` to match any string except
                        "example" (negative lookahead).
  --member-severity {ok,warn,crit,unknown}
                        State to report when the kernel says a member device
                        wants replacing, has seen a write error, or has bad
                        blocks that are not acknowledged yet. None of the
                        three reaches /proc/mdstat, so an array carrying one
                        of them still reads as complete. Default: warn
  --mirror-mismatch-severity {ok,warn,crit,unknown}
                        State to report when a consistency check found
                        inconsistent sectors on a mirrored array (RAID 1, RAID
                        10). A page written while the check reads it, and
                        above all a swap area, produce differences between the
                        copies that nothing ever reads back, which is why this
                        defaults to not alerting. Default: ok
  --mismatch-severity {ok,warn,crit,unknown}
                        State to report when a consistency check found
                        inconsistent sectors on a parity array (RAID 4, RAID
                        5, RAID 6). On such an array the difference points at
                        hardware rather than at the way the data was written.
                        Default: warn
  --no-arrays-severity {ok,warn,crit,unknown}
                        State to report when the host runs no software RAID
                        array at all. An array is assembled from the
                        superblocks on its members at every boot, so an array
                        that used to be here and is gone is worth looking at.
                        Default: warn
  --no-match-severity {ok,warn,crit,unknown}
                        State to report when no item matches the filters and
                        nothing is checked. Default: ok
  --no-perfdata         Suppress the performance data section from the output.
                        The status message and the exit code are unaffected,
                        so alerting keeps working while trending data is
                        dropped.
  --severity {ok,warn,crit,unknown}
                        Severity for alerting. Applies to an array that is
                        running on fewer members than it was built for, so it
                        has lost the redundancy it is meant to provide, and to
                        a member the kernel threw out that is still attached
                        to an array a spare has already brought back to its
                        full width. Default: warn
  --spares SPARES       Number of spare devices an array is expected to hold.
                        A bare count applies to every array, `array=count`
                        pins one array and wins over the bare count. The array
                        is named by its kernel device or by the name it was
                        created under. Can be specified multiple times.
                        Example: `--spares=1` on a host where every array
                        carries one hot spare. Example: `--spares=md0=1
                        --spares=md1=0` where only the first one does.
                        Default: None, which grades no array against a spare
                        count.
  --spares-severity {ok,warn,crit,unknown}
                        State to report when an array holds fewer spare
                        devices than --spares says it should. Without a spare
                        the next member the kernel throws out leaves the array
                        degraded until somebody puts a disk in. Default: warn

Documentation:
https://linuxfabrik.github.io/monitoring-plugins/check-plugins/md-raid/

Usage Examples

./md-raid

Output on a host whose arrays are all complete:

2 software RAID arrays, all of them intact.

Array ! Level ! Devices    ! State
------+-------+------------+-------
md0   ! raid1 ! 2/2 [UU]   ! active
md1   ! raid5 ! 4/4 [UUUU] ! active

Output while an array rebuilds onto a spare after a disk was replaced:

md0: recovery 1.5%, 1m left, 2.0MiB/s, degraded, running on 1 of 2 devices.
md0 is already rebuilding onto a replacement, so let it finish. The member the kernel threw out (vda) can be taken out at any point with `mdadm /dev/md0 --remove /dev/vda`. Until the rebuild is done, the array has no redundancy left to lose.

Array ! Level ! Devices  ! State
------+-------+----------+-------------------
md0   ! raid1 ! 1/2 [_U] ! degraded [WARNING]

A running resync, recovery, reshape or check always leads that first line, because whether an array is already healing decides what happens next, and the first line is the only part of the output a service list and a notification show.

Output after a spare finished rebuilding, where the array is complete again and the dead disk is still in it:

md1: complete again but still carrying 1 failed member (vdc).
The array is back to its full width, so a spare has stepped in or the member was replaced, and the device the kernel threw out is still attached. Take it out with `mdadm /dev/md0 --remove /dev/sdb1` and put a new spare in, because the next failure has nothing left to fall back on.

Array ! Level ! Devices   ! State
------+-------+-----------+----------------------------------
md1   ! raid5 ! 3/3 [UUU] ! failed member attached [WARNING]

Output on an array the kernel has given up on:

md0: broken.
The kernel has stopped serving this array. Do not write to it and do not recreate it: `mdadm --assemble --force` on the members that are still readable is the way back, and it needs the members left untouched.

Array ! Level ! Devices  ! State
------+-------+----------+------------------
md0   ! raid1 ! 0/2 [__] ! broken [CRITICAL]

--lengthy adds the metadata version, the members carrying a flag, the inconsistent sectors from the last consistency check and what the array is currently doing:

./md-raid --lengthy
md5: reshape 2.7%, 1m 6s left, 1.8MiB/s.

Array ! Name ! Level ! Devices    ! Metadata ! Flagged Members ! Mismatches ! Sync                               ! State
------+------+-------+------------+----------+-----------------+------------+------------------------------------+-------
md5   ! -    ! raid5 ! 4/4 [UUUU] ! 1.2      ! -               ! 0          ! reshape 2.7%, 1m 6s left, 1.8MiB/s ! active

The flagged members are the ones the kernel says something about, from either of the two places it says it. /proc/mdstat gives faulty for a member it threw out, spare for one waiting to be pulled in, replacement for one being built up next to the member it replaces, write-mostly for a mirror leg reads avoid, and journal for the write journal of a parity array. Next to the array it gives want_replacement, write_error and blocked, in its own spelling so they can be grepped for in /sys and in the kernel log. A member neither of them says anything about is doing its ordinary job and is not listed.

Output on a parity array whose write journal is gone. /proc/mdstat reports [3/3] [UUU] and the array accepts no writes:

md0: write journal lost, so writes to this array fail and buffered ones are thrown away.
md0 keeps its write journal on a device of its own, and that device is dead. Reads still work and writes do not: a direct write answers with an I/O error, and a buffered write is reported as having succeeded while the kernel throws it away, so an application on top of this array is losing data right now without being told. Nothing in /proc/mdstat says so, it keeps reporting every member in sync. Take the dead journal out with `mdadm /dev/md0 --remove /dev/vdf`, then put a new one in: `mdadm --readonly /dev/md0` first, because `--add-journal` is refused on a running array, then `mdadm /dev/md0 --add-journal` followed by the device. mdadm switches the array back to read-write by itself at that point, so no `--readwrite` is needed afterwards. Where there is no disk to spare, `echo resync > /sys/block/md0/md/consistency_policy` gives up journalling instead and makes the array writable again immediately, at the price of the write hole the journal was there to close.

Array ! Name ! Level ! Devices   ! Metadata ! Flagged Members       ! Mismatches ! Sync ! State
------+------+-------+-----------+----------+-----------------------+------------+------+------------------------
md0   ! -    ! raid5 ! 3/3 [UUU] ! 1.2      ! vdf (journal, faulty) ! 0          ! idle ! journal lost [CRITICAL]

Output where the array is at its full width and the kernel is unhappy about its members all the same. This is what nothing in /proc/mdstat shows:

md0: vda has unacknowledged bad blocks, so writes to it wait, vdb is marked for replacement, vdc has seen a write error.
The kernel publishes this next to md0 and not in /proc/mdstat, so the line the array itself gets says nothing about it. Look at the health of the disks behind vda, vdb, vdc with `smartctl --all` on each of them and at what the kernel said with `journalctl --dmesg --grep=md`. A member the kernel wants replaced is replaced by putting a spare in with `mdadm /dev/md0 --add` followed by a device: the kernel builds the spare up and takes the old member out by itself. Writes to a blocked member wait until the bad blocks behind it are acknowledged, and `cat /sys/block/md0/md/dev-vda/unacknowledged_bad_blocks` lists them.

Array ! Name ! Level ! Devices   ! Metadata ! Flagged Members                                          ! Mismatches ! Sync ! State
------+------+-------+-----------+----------+----------------------------------------------------------+------------+------+-------------------------
md1   ! -    ! raid1 ! 2/2 [UU]  ! 1.2      ! -                                                        ! 0          ! idle ! active
md0   ! -    ! raid1 ! 3/3 [UUU] ! 1.2      ! vda (blocked), vdb (want_replacement), vdc (write_error) ! 0          ! idle ! member flagged [WARNING]

Output on a degraded array with a spare in it that is not rebuilding, because its sync is frozen. The instruction says what has to happen before anything else, and does not ask for a device the array already has:

md0: sync frozen, degraded, running on 2 of 3 devices.
md0 lost vdc. Look at what the kernel said about it (`journalctl --dmesg --grep=md`) and at the health of the disk carrying that member (`smartctl --all` on the disk it sits on) before writing it off. Then take it out with `mdadm /dev/md0 --remove /dev/vdc` and replace the hardware. A spare is attached to md0 already (vdd), so nothing has to be added for the rebuild itself. Nothing rebuilds while the sync of md0 is frozen, so `echo idle > /sys/block/md0/md/sync_action` comes before any of it.

Array ! Level ! Devices   ! State
------+-------+-----------+-------------------
md0   ! raid5 ! 2/3 [UU_] ! degraded [WARNING]

On a host where a lost RAID member is a reason to act at night:

./md-raid --severity=crit

On a mirror over a swap area, where the mismatch count is expected to move and only the redundancy matters:

./md-raid --mirror-mismatch-severity=ok

On a host where every redundant array carries one hot spare:

./md-raid --spares=1

Where only one of them does, pin the count per array. The array is named by its kernel device or by the name it was created under:

./md-raid --spares=0 --spares=md2=1
md2: degraded, running on 3 of 4 devices, short of 1 spare device.
md2 lost vde. Look at what the kernel said about it (`journalctl --dmesg --grep=md`) and at the health of the disk carrying that member (`smartctl --all` on the disk it sits on) before writing it off. Then take it out with `mdadm /dev/md2 --remove /dev/vde` and replace the hardware. The replacement goes in with `mdadm /dev/md2 --add` followed by its device. The array rebuilds on its own from there. Until it is done, it has no redundancy left to lose.
md2 holds 0 of the 1 spare device it is expected to, so the next member the kernel throws out has nothing to be rebuilt onto and the array stays degraded until somebody puts a disk in. `mdadm /dev/md2 --add` followed by a device puts one in now.

Array ! Level  ! Devices    ! State
------+--------+------------+-------------------
md2   ! raid10 ! 3/4 [_UUU] ! degraded [WARNING]
md1   ! linear ! 2          ! active
md0   ! raid0  ! 2          ! active

Leave a single array out, for example one that is deliberately kept degraded:

./md-raid --ignore='^md9$'

States

  • OK if every array is running on all the members it was built for and no reported consistency check found anything.
  • WARN if an array is running on fewer members than it was built for. --severity lowers that to ok or raises it to crit or unknown.
  • WARN if a member the kernel threw out is still attached to an array that is back to its full width, which is what a spare taking over leaves behind. --severity applies here too.
  • WARN if the kernel says a member wants replacing, has seen a write error, or has bad blocks that are not acknowledged yet. None of the three shows up in /proc/mdstat. --member-severity changes it.
  • WARN if an array holds fewer spare devices than --spares says it should. --spares-severity changes it. Without --spares no array is graded against a spare count.
  • WARN if the last consistency check on a parity array (RAID 4, RAID 5, RAID 6) found inconsistent sectors. --mismatch-severity changes it.
  • OK with the count reported if the last consistency check on a mirror (RAID 1, RAID 10) found inconsistent sectors. --mirror-mismatch-severity raises it.
  • CRIT if a parity array has lost the write journal it keeps on a device of its own. Such an array reports every member in sync and cannot be written to. --journal-severity changes it.
  • CRIT if the kernel reports an array as broken, which is its own word for an array that can no longer serve its data.
  • CRIT if an array is inactive, which means it was assembled but never started.
  • WARN if the host runs no software RAID array at all, and WARN with a different explanation on a kernel that has no md support loaded, which are two different statements. --no-arrays-severity changes both.
  • OK if --match and --ignore leave nothing to check. --no-match-severity raises that.
  • UNKNOWN if --match or --ignore is not a valid Python regular expression.
  • UNKNOWN if the check does not run on Linux.
  • --always-ok suppresses all alerts and always returns OK.

Perfdata / Metrics

The array counts are taken after --match and --ignore have been applied, so an array silenced with --ignore is out of the graph as well.

Name Type Description
arrays Number Software RAID arrays the kernel knows about.
arrays_broken Number Arrays the kernel can no longer serve data from.
arrays_degraded Number Arrays running on fewer members than they were built for.
arrays_inactive Number Arrays that were assembled but never started.
arrays_journal_lost Number Parity arrays that have lost their write journal and therefore accept no writes.
arrays_sync_frozen Number Arrays whose sync is frozen, so they neither resync, recover nor reshape.
arrays_syncing Number Arrays with a resync, recovery, reshape or consistency check running.
devices_faulty Number Member devices the kernel has thrown out, across all arrays.
devices_flagged Number Member devices the kernel wants replaced, has seen a write error on, or has unacknowledged bad blocks for, across all arrays.
devices_spare Number Member devices standing by across all arrays, waiting to be pulled in.
devices_spare_missing Number Spare devices missing against --spares, across all arrays. Stays at 0 without --spares.
array_mismatch_cnt Number Inconsistent sectors the last consistency check found on this array, one metric per array.
array_sync_bytes_per_second Bytes Speed of the running resync, recovery, reshape or consistency check. Only reported while one runs.
array_sync_percent Percentage Progress of the running resync, recovery, reshape or consistency check. Only reported while one runs.

Troubleshooting

An array is degraded

The kernel threw a member out, or a member never turned up. The array still serves its data and has no redundancy left to lose, so this is worth doing today rather than this week.

  1. Find out which member is gone and what the kernel said about it:

    bash cat /proc/mdstat mdadm --detail /dev/md0 journalctl --dmesg --grep=md

  2. Look at the disk behind it before you decide it is dead. A member is also thrown out by a cable, a backplane or a controller reset:

    bash smartctl --all /dev/sdb

  3. Take the failed member out of the array, replace the hardware, and partition the new disk the same way as its neighbour:

    bash mdadm /dev/md0 --remove /dev/sdb1 sfdisk --dump /dev/sda | sfdisk /dev/sdb

  4. Add it back. The array starts rebuilding by itself, and this check reports the progress until it is done:

    bash mdadm /dev/md0 --add /dev/sdb1

    On an array that is read-only, this fails with add new device failed [...]: Read-only file system, because the kernel refuses every superblock-changing operation there. Make it writable first:

    bash mdadm --readwrite /dev/md0

    An array that is only auto read-only needs nothing of the sort, the kernel switches it over by itself at that point. The check names the state in its output and adds the step where it applies.

  5. On a boot disk, put the boot loader on the new member as well. A mirror only boots from the disk that carries one:

    bash grub2-install /dev/sdb # Red Hat family grub-install /dev/sdb # Debian family

Where the rebuild is slow enough to matter, the ceiling is a kernel-wide setting and not a property of the array:

cat /proc/sys/dev/raid/speed_limit_max
echo 200000 > /proc/sys/dev/raid/speed_limit_max

An array is complete again but still carries a failed member

A spare took over and the rebuild finished, so the array has its full width back. The device the kernel threw out is still attached, and the array has used up the spare it had.

  1. Take the dead member out:

    bash mdadm /dev/md0 --remove /dev/sdb1

  2. Replace the hardware and put a new spare in, so the next failure has something to fall back on again:

    bash sfdisk --dump /dev/sda | sfdisk /dev/sdb mdadm /dev/md0 --add /dev/sdb1

    On an array that is already at its full width, --add puts the new device in as a spare rather than starting a rebuild.

md0: write journal lost

A RAID 4, 5 or 6 array can keep a write journal on a device of its own, which closes the write hole: a stripe that was half written when the power went is reconstructed from the journal instead of being silently wrong. Where that device is gone, the array keeps reporting every member in sync and stops accepting writes. Reads are unaffected, a direct write gets Input/output error, and a buffered write is reported to the application as having succeeded and then dropped. Anything writing to this array is losing data now.

  1. Take the dead journal out, if one is still attached:

    bash mdadm /dev/md0 --remove /dev/sdf

  2. Put a new journal in. The array has to be read-only for this, --add-journal is refused on a running array:

    bash mdadm --readonly /dev/md0 mdadm /dev/md0 --add-journal /dev/sdf

    text mdadm: Journal added successfully, making /dev/md0 read-write mdadm: added /dev/sdf

    mdadm switches the array back to read-write by itself, so no mdadm --readwrite follows. Running it anyway answers failed to set writable for /dev/md0: Device or resource busy.

  3. Where there is no disk to spare, give up journalling instead. The array becomes writable again immediately and loses the write-hole protection the journal provided:

    bash echo resync > /sys/block/md0/md/consistency_policy

    mdadm --grow --consistency-policy=resync does not do this on a running array; it answers Current consistency policy is journal, cannot change to resync.

The kernel says a member wants replacing, has seen a write error, or is blocked

The array itself reports nothing: it is at its full width, /proc/mdstat shows [3/3] [UUU], and the kernel is unhappy about one of the members all the same. All three words come from /sys/block/md0/md/dev-sdb1/state and mean a disk that is on its way out rather than one that is gone.

  1. Ask the disk what it thinks, and read what the kernel logged about it:

    bash smartctl --all /dev/sdb journalctl --dmesg --grep=md

  2. On blocked, list the bad blocks nobody has acknowledged yet. Writes to the member wait for that, so this is the one of the three that costs I/O right now:

    bash cat /sys/block/md0/md/dev-sdb1/unacknowledged_bad_blocks

  3. On want_replacement, put a spare in. The kernel builds it up and takes the old member out by itself, with the array staying redundant throughout, which is the difference from failing the member by hand:

    bash sfdisk --dump /dev/sda | sfdisk /dev/sdc mdadm /dev/md0 --add /dev/sdc1

  4. On write_error the kernel absorbed a failed write into the bad block list instead of throwing the member out. The array kept working and the disk below it did not, so plan the replacement rather than waiting for the member to fail.

A degraded array is not rebuilding

sync_action reads frozen, which forbids resync, recovery and reshape. Nothing clears it by itself, so somebody set it and left it set, either by hand or through a script that froze the sync for a maintenance window and never thawed it. Until it is thawed the array does not rebuild, however many spares are sitting in it, and adding another device changes nothing.

  1. Let the sync run again:

    bash echo idle > /sys/block/md0/md/sync_action

  2. Watch the rebuild start. A spare that was already attached is pulled in without anything else being done:

    bash cat /proc/mdstat

An array is short of a spare

--spares says the array should hold more spare devices than it does. Either the spare was pulled in when a member failed and nobody put a new one in, or the disk carrying it is gone.

  1. See what the array holds, and whether the disk that carried the spare is still there:

    bash cat /proc/mdstat lsblk

  2. Put a spare in. On an array that is already at its full width, --add adds the device as a spare rather than starting a rebuild:

    bash sfdisk --dump /dev/sda | sfdisk /dev/sdc mdadm /dev/md0 --add /dev/sdc1

md0 is broken

The array has lost more members than its RAID level can survive, and the kernel has stopped serving it. What is on it is not lost yet, but the next few commands decide whether it stays that way.

Do not write to the array, and above all do not run mdadm --create on the members: that writes new superblocks and destroys the only record of how the data was laid out.

  1. Read what each member still says about itself. The event counters tell you which members dropped out first:

    bash mdadm --examine /dev/sd[a-d]1

  2. Assemble the array from the members whose event counters are closest together. --force tells mdadm to accept the small difference between them:

    bash mdadm --stop /dev/md0 mdadm --assemble --force /dev/md0 /dev/sda1 /dev/sdc1

  3. Where that comes up, mount it read-only and copy the data off before doing anything else:

    bash mount -o ro /dev/md0 /mnt

A member that is physically fine but was thrown out by a transport error usually comes back this way. A member with unreadable sectors does not, and that is where the backup comes in.

md0 is inactive

The array exists but was never started, because not enough of its members turned up at boot. This is the normal outcome when a disk is missing, when a controller enumerates late, or when /etc/mdadm.conf names an array whose members were moved.

mdadm --detail /dev/md0
mdadm --examine --scan

The first command names the members the kernel has, the second the ones the superblocks on the attached disks describe. Where the missing member is simply late, starting the array by hand is enough:

mdadm --run /dev/md0

Where it is really gone, start the array degraded on the members that are there and treat it like the degraded case above:

mdadm --stop /dev/md0
mdadm --assemble --force --run /dev/md0 /dev/sda1

No software RAID array on this host

/proc/mdstat is there, so the kernel has the md code, and it lists no array. Either the arrays were dismantled, or their members did not turn up at boot.

cat /proc/mdstat
mdadm --examine --scan

Where the second command prints array definitions and the first does not, the superblocks are still on the disks and only the assembly failed; put what it prints into /etc/mdadm.conf (Red Hat family) or /etc/mdadm/mdadm.conf (Debian family), rebuild the initial ramdisk and reboot.

Where both come up empty, this host has no software RAID and the check does not belong on it. Until it is taken off, silence it:

./md-raid --no-arrays-severity=ok

This kernel has no software RAID support loaded

There is no /proc/mdstat at all. The md code reaches the kernel with the first array that is assembled, so a host that never had one does not carry the file, and this message means the check landed on a host that has never run software RAID.

An installed mdadm package says nothing either way: on the Red Hat family it sits in @baseos and the initial ramdisk pulls it in, so it is present on hosts that will never assemble an array. That is why the check is rolled out by the presence of an array rather than by the package.

Where this host is supposed to run an array, the superblocks on the disks say what it was:

mdadm --examine --scan
mdadm --assemble --scan

Where it is not, take the check off the host, and silence it until then:

./md-raid --no-arrays-severity=ok

A consistency check found inconsistent sectors

On a parity array (RAID 4, RAID 5, RAID 6) md(4) says this points at a hardware problem at some level, because software alone does not produce it. On a mirror (RAID 1, RAID 10) it can just as well be a page that was written while the check was reading it, which is why the check does not alert on that by default.

  1. Look for the disk behind it first. A mismatch that comes back to the same array over and over has a cause in the hardware:

    bash smartctl --all /dev/sdb journalctl --dmesg --grep=md

  2. Rewrite the parity, or bring the copies back in line, and watch the count go back to zero:

    bash echo repair > /sys/block/md0/md/sync_action cat /proc/mdstat

  3. Run another check afterwards. Only that second run says whether the repair held:

    bash echo check > /sys/block/md0/md/sync_action cat /sys/block/md0/md/mismatch_cnt

On a mirror carrying swap, the count moves on a healthy system and never goes to zero for long. Leave --mirror-mismatch-severity at its default there and watch the graph instead.

The count of inconsistent sectors never changes

Nothing has run a consistency check. mismatch_cnt holds whatever the last check or repair left behind and is reset to zero when the next one starts, so on a host where no check ever runs the number says nothing at all.

Both distribution families ship the job, and both leave it to the administrator to enable it:

systemctl enable --now mdcheck_start.timer     # Red Hat family, and Debian 12 upwards
systemctl list-timers 'mdcheck*'

On the Debian family the same work is done by /etc/cron.d/mdadm, which runs checkarray on the first Sunday of the month. Check that AUTOCHECK is not switched off in /etc/default/mdadm.

A RAID 0 array reports active although a disk is broken

Correct and not a defect. RAID 0 and linear arrays have no redundancy, so md keeps no state about the health of their members: there is no degraded attribute, no consistency check, and a member is never marked faulty. As long as the disk is still attached, a member that returns nothing but I/O errors leaves the array reporting active, and the errors reach whoever is reading.

The array only turns broken once the member is really gone from the system, and even then on the first I/O that touches it rather than at the moment it disappeared.

What covers this instead is the health of the disks themselves:

smartctl --all /dev/sdb

Deploy disk-smart on hosts whose data sits on a RAID 0.